ebook-mobile-banner-fp-part-1

1. Fiber Photometry Overview

1.1 What Is Fiber Photometry

Behavioural neuroscientists seek to understand how neural circuits give rise to behaviour and cognition. This endeavor is methodologically and epistemologically founded, in part, upon measuring changes in the activity of neural circuits during specific behaviours and/or cognitive processes. Researchers now have an arsenal of methods for monitoring brain activity during behaviour, including a family of optical recording methods which leverage recent advances in neurophotonics and activity-dependent, genetically-encoded fluorescent indicators. These methods provide a view into the brain with high spatiotemporal resolution and genetic specificity. Among these optical recording methods, fiber photometry is perhaps the most rudimentary, but as we will discuss, this simplicity also gives way to some major advantages and extremely powerful applications.

Fiber photometry is a method for recording “bulk” cellular activity in vivo while animals are freely behaving. This involves first modifying a cell population with an activity-dependent fluorescent indicator which can be excited by a specific range of visible light wavelengths and, in turn, emits fluorescence at a different range of wavelengths. An intracranial optical fiber is then implanted within this cell population, excitation light is delivered to the brain through an optical fiber patch cord, and the emission light travelling back through the patch cord is filtered and measured by a photodetector. The optical fiber patch cord is flexible and can be of an ample length without noticeable power loss, so animals are free to move and perform behavioural tasks while this recording takes place.

The most common fluorescent indicators used in neuroscience increase their brightness when bound to a specific ligand (e.g. Ca+2 ion entering the cell during an action potential). This results in an “intensiometric” read-out where an increase in indicator brightness is interpreted as an increase in neural activity. However, one of the primary challenges in fiber photometry is that many sources of noise can affect this brightness read-out and without the ability to visualize individual cells during recording, this noise could be mistaken for real signal. This is usually dealt with by including a secondary excitation wavelength either to excite the indicator at its “isosbestic point” (the excitation wavelength at which the indicator emits fluorescence but with minimal influence from activity) or a separate control indicator in a different spectral range. The assumption is that this “control channel” will contain the noise that pollutes the “signal channel”, but not the activity-dependent signal1. Alternative approaches involve indicators with multiple photosensitive domains which give either ratiometric or fluorescence lifetime-based readouts without the need for a control channel, but this eBook will focus on the most common intensiometric approach.

Following the appropriate preprocessing of the raw signal, a time series can be produced that contains the summed fluorescent signal from the indicator-expressing cells that fall within the light collection field of the fiber optic probe. This signal is then synchronized with a time series of behavioural events and/or other experimental manipulations. This event-related analysis yields a pattern of population-level activity changes during specific behaviours, events, drug conditions, or disease states.

ebook-fiber-photometry-part-1-fig1

Figure 1. Comparison of cellular-resolution imaging and bulk fiber photometry. The left panel illustrates cellular-resolution signal collection using a GRIN lens, capturing fluorescence from individual indicator-expressing neurons within the field of view. The right panel depicts bulk fluorescence measured by fiber photometry, represented as a summed population signal that can be temporally aligned with behavioral events or experimental manipulations to assess population-level activity dynamics.

The first published experiments using Fiber Photometry came in the mid-2000s beginning with the seminal 2005 paper by Adelsberger, Garaschuk & Konnerth 1. These authors pioneered fiber photometry by imaging calcium waves in the cortex of newborn mice. Their hardware configuration included a laser light source, beam splitter, and implanted optic fiber. Since then, huge technological and conceptual advancements have been made, and fiber photometry has developed into a mature, highly popular methodology for recording brain activity in vivo.

1.2 Recent Progress in Fiber Photometry

1.2.1 Advances in Fluorescent Indicators

One of the most significant advancements that has facilitated the application of fiber photometry to a wide range of questions is the rapid expansion in the performance and varieties of Genetically-encoded Fluorescent Indicators (GEFI). There is now a wide array of GEFIs that sense Ca22+ flux, neurotransmitter binding, voltage, and intracellular signaling dynamics. Successive generations of these sensors have vastly improved in brightness, the speed of their on/off kinetics, and their ligand binding selectivity. For instance, as of the time of writing this document, there have been 8 generations of the GCaMP sensor representing massive improvements on the original version.

With ever-increasing brightness and speed, researchers are able to record from sparser and smaller targets as well as resolve finer dynamics. Improvements in ligand binding selectivity now allow unprecedented access to specific neuromodulator activity. For example, researchers can now separate the dynamics of dopamine and norepinephrine, which normally exhibit significant crosstalk as a consequence of their similar molecular structure and co-release from the same neurons. These GEFIs are also now available with various excitation/emission spectra, enabling multi-colour recording experiments in which the activity of 2 or even 3 GEFIs can be measured at the same recording site and cross-correlated.

ebook-fiber-photometry-part-1-fig2

Figure 2. Illustration of the molecular structure of GCaMP in its calcium-bound and unbound states.

1.2.1 Advances in Fluorescent Indicators

Another area of major advancement is the refinement and proliferation of purpose-built fiber photometry hardware. Whereas the earliest fiber photometry systems had to be custom-designed and built by users, companies like Mightex now offer plug-and-play, versatile, and scalable fiber photometry hardware along with extensive product consultation and training. These systems now incorporate multiple wavelengths for simultaneous imaging of multiple GEFIs and an isosbestic control channel, performing simultaneous optogenetics, I/O interfaces for synchronization with behaviour systems, and dedicated software. The latest generation of systems also typically use LED light sources which present less risk of phototoxicity and are generally cheaper. Moreover, major advancements have been made in designing photometry systems for simultaneous recording of multiple brain regions and animals. Multifurcated fiber optic patch cords paired with the latest scientific cameras allow simultaneous recordings of entire groups of animals and/or multiple brain regions without the need to purchase multiple systems.

2. Why and When to Use Fiber Photometry

2.1 Specificity for Cell Types, Projection Pathways, and Neurochemicals

Optical neural recording methods may often lack the temporal precision of electrophysiological methods and are not a direct measurement of spiking (although this is rapidly changing with the advent of fluorescent voltage sensors). However, where they vastly outperform in vivo electrophysiology is their capability to be highly specific to cell-types, subcellular components (such as cell bodies versus projections/terminals), and specific neurochemical activity. This specificity is accomplished via genetic targeting via viral vectors and/or transgenes.

2.1.1 Viral Vectors

The most common types of viral vector currently used in neuroscience are adeno-associated viral vectors (AAV). They are favoured for their relatively low toxicity in addition to possessing some extremely useful capabilities for specific targeting of cell subtypes and subcellular components.

Projection Mapping

AAVs can efficiently transduce cell bodies, but they are also capable of axonal transport, with specific serotypes having been developed to facilitate retrograde transport. Given the fact that an individual brain region receives extremely diverse inputs from multiple other regions, in addition to sending diverse outputs to multiple locations, the ability to target and isolate the activity of a single projection pathway is critical. Researchers can, for example, infuse a retrograde AAV into a brain region where it will transduce afferent axon terminals and begin expressing in the cell bodies of an upstream projection area, enabling the recording of the cell bodies of projection neurons sending efferents to a specific region 2. The reverse is also possible, wherein researchers can infuse an AAV into a projection region and then record from the axon terminals in the target region 3.

Promotor-driven Targeting of Cellular Subtypes

AAVs can also be expressed under different endogenous promoters so that GEFI expression is amplified within the cell populations containing the complementary genetic sequence. While generally affording less precision than the cre driver systems discussed below, this does provide some targeting to specific cell populations. For example, researchers have successfully used an AAV containing the mDlx promoter to preferentially target inhibitory neurons 4. This approach offers a potential workaround in cases where no cre driver animal line is available.

2.1.2 Transgenic Animal Lines

Where genetic targeting becomes truly powerful is the use of cre-dependent AAVs in cre driver animal lines to target GEFIs to specific cell subtypes. These animals express a transgene within a given cell subtype encoding cre recombinase, allowing researchers to use a cre-dependent AAV resulting in GEFI expression only 2 in a specific cell type. There are now a myriad of transgenic mouse lines (and increasingly, rats as well) allowing cre-dependent viral expression in many cell types. This technology is now used extensively to study the activity and function of various interneuron subtypes during behaviour 5, for example. There are even activity-dependent labelling systems that allow viral constructs to be expressed only in the neurons that were active during a specific experience 6, such as the neuronal population encoding a specific memory.

ebook-fiber-photometry-part-1-fig3

Figure 3. Illustration of genetic targeting using Cre-dependent viral expression. Multiple neuronal cell types are depicted, with selective expression of a genetically encoded fluorescent indicator confined to a specific cell subtype. This selectivity enables precise targeting of genetically defined neuronal population for functional imaging and activity-dependent studies.

2.1.3 Neurotransmitter-selective GEFIs

Studying the function of endogenous neurotransmitter dynamics in vivo is challenging. Neurons often co-release multiple neurotransmitters packaged within the same vesicles. The neurotransmitters that are co-released can drive opposite behavioural effects when examined in isolation, as was recently shown in glutamate/dopamine co-releasing neurons in the VTA 7. In spite of some enduring advantages, older methods for measuring in vivo neurotransmitter release present some critical drawbacks with respect to addressing these complexities. Microdialysis can allow measurement of absolute neurotransmitter concentration with extremely high precision, but the temporal resolution is far too low to capture fast, phasic neurotransmitter dynamics. Fast Scan Cyclic Voltammetry has superior temporal resolution but cannot distinguish between catecholamines. Moreover, neither of these methods can isolate neurotransmitter dynamics in individual cell subtypes or projection pathways.

Recently, there has been rapid progress in the development of GEFIs that respond to specific neurotransmitters such as glutamate, GABA, and dopamine. Neurotransmitter-selective GEFIs such as the GRAB sensor family 8–10 offer a very effective middle road with regard to their high temporal resolution and ligand selectivity with the enormous advantage of cell subtype and projection pathway specificity. These neurotransmitter sensors are now enabling the study of neurotransmitter release dynamics during behaviour with an unprecedented combination of temporal resolution, neurochemical precision, and genetic specificity. They are available in multiple emission wavelengths, allowing simultaneous recording and cross-correlation of multiple neuromodulator dynamics or a neuromodulator and a Ca22+ indicator.

2.2 Easy and Reliable

Fiber photometry represents in vivo optical recording at its simplest. It is a relatively easy, simple entry point for users new to optical recording methods in neuroscience. The experimental procedures for surgery and recording are easy and accessible and the datasets produced are easily handled without huge computing power requirements or highly-advanced statistical programming skills. Moreover, the equipment required is relatively simple in principle, essentially just consisting of excitation light sources, a few filters, a fiber optic patch cord to connect the subject, and a light detector. These components are relatively durable, reliable, and in the case of Mightex fiber photometry solutions, can be interchanged in a straightforward, modular fashion to suit different experimental needs.

labelled-photometry-systems-smushed-vertically

Figure 4. Labelled image of the OASIS Photometry system.

2.2.1 Safe and Simple Surgeries

The surgeries required for fiber photometry are far less invasive than for in vivo cellular resolution optical recording, which often require multiple lengthy surgeries involving large craniotomies and sometimes involve aspirating away large volumes of tissue to clear a path for a GRIN lens. For fiber photometry, viral vectors can be infused, a fiber implanted, and a headcap built within a single surgery lasting less than an hour (for an experienced surgeon). The indwelling fiber is small (usually 0.4 mm diameter) which causes greatly reduced tissue displacement compared with the GRIN lenses, requires no aspiration, and only a small craniotomy. Moreover, the imaging window, which requires time to be cleared of blood and inflammation, also tends to clear more rapidly than with GRIN lenses.

ebook-fiber-photometry-part-1-fig5a
ebook-fiber-photometry-part-1-fig5b

Figure 5. Sagittal mouse brain schematics illustrating multiple optical fibers implanted across distinct regions (left) and a single GRIN lens implanted for localized imaging (right).

ebook-fiber-photometry-part-1-fig6

Figure 6. A depiction of the surgical timeline for photometry.

Combined, these factors mean that fiber photometry experiments do not suffer from high attrition rates that often plague cellular resolution imaging or voltammetry experiments, where a substantial proportion of subjects can be lost to various failure points before recording has even commenced. Experienced surgeons working with a well-validated sensor and surgical protocol can expect close to 100% success rates – a major advantage when trying to conserve animals which are especially precious due to their transgenic breeding, expensive long-term drug treatments, or extensive behavioural training. Highly time-dependent experiments such as those examining neurodevelopmental or neurodegenerative processes are also much easier due to the fast post-operative recovery and rapid imaging window clearance.

2.2.2 Light Datasets and Simple Analysis

Fiber photometry produces much smaller datasets than cellular resolution recordings. A photometry recording is saved as a .csv file which is orders of magnitude smaller than the BigTIFF image stacks acquired in cellular resolution recordings. This makes datasets more shareable across labs, enabling more open science. Large repositories of photometry data can be stored locally or on the cloud without massive, dedicated data storage.

Fiber photometry analysis also does not typically impose onerous computational requirements, such as the complex motion correction and ROI identification algorithms required for cellular resolution imaging analysis. Whereas cellular resolution imaging analysis might require a high-end computer with dozens of CPU cores (or a user willing to wait overnight for their code to finish running on just one recording session), photometry datasets can usually be analyzed on a consumer-quality laptop with acceptable efficiency.

Data analysis is also conceptually straightforward. Each animal/recording site/GEFI produces a single trace. For the most basic analyses, these traces need only undergo a few steps of preprocessing, synchronization with a behaviour timeseries, and reorganization into peri-event data. Cellular resolution recordings result in hundreds of traces for each recording, multiplying the complexity of statistical modelling and introducing additional hurdles such as inter-session cell registration. Photometry data can of course be subjected to more sophisticated statistical approaches, but it lends itself to a much less daunting initial buy-in.

Finally, photometry data analysis does not necessarily require one to be an expert statistical programmer. Although any photometry user will benefit from some rudimentary Python or MATLAB coding skills, there is now a wealth of commercial, as well as open source, photometry analysis pipelines. Commercial solutions such as Mightex’s Polyscan software can conveniently deinterleave photometry traces collected from multiple regions or animals into their individual fluorescent channels and timestamps and export recordings as .csv files easily readable by the majority of analysis pipelines.

2.3 High-throughput and Versatile

2.3.1 Multiple Animals

Fiber photometry offers the ability to easily record from multiple animals simultaneously. Solutions such as Mightex’s OASIS Turnkey Fiber Photometry System can record up to 19 animals simultaneously on just one system via the use of multifurcated fiber optic patch cords. This attribute has obvious advantages including the conservation of personnel time and the ability to more rapidly collect large datasets. Ultimately, this facilitates experiments with larger sample sizes for more reliable, reproducible science.

2.3.1 Multiple Wavelengths

With the current explosion in availability of neurotransmitter sensors in a variety of colours, fiber photometry offers the critical element of technical flexibility to cheaply and conveniently adapt the hardware for various combinations of GEFIs and multicolour imaging. A new generation of far red GRAB sensors has opened the possibility of simultaneously imaging 3 sensors (green, red, far red) allowing complex analyses of the interplay between neuronal activity and multiple neuromodulator dynamics. At the time of writing, Mightex’s OASIS Fiber Photometry Turnkey System is the only system on the market with the ability to perform quadruple-colour recording (3 GEFIs, 1 isosbestic) and can be easily customized with different LED wavelengths and filter sets to quickly adapt the hardware configuration for various multicolour recording experiments.

2.3.1 Multiple Sites

Because fiber optic implants are generally very compact, researchers have wide latitude to implant multiple fibers aimed at different brain regions in order to study projection dynamics and functional connectivity among different brain regions. Although recent technology has enabled freely-moving, multiregion recording at cellular resolution, the fiber optic implants used in fiber photometry still have a smaller diameter than the smallest GRIN lens, meaning less tissue trauma. These implants also have a much smaller skull footprint than even the most compact GRIN lens headmount assemblies used with cellular resolution fiberscopes. Thus, fiber photometry remains the most flexible solution for experiments involving, for example, functional connectivity mapping across multiple brain regions.

ebook-fiber-photometry-part-1-fig7

Figure 7. Our suite of OASIS Photometry systems; Basic, Integrated Optogenetics, and ROAM can facilitate fiber furcations to multiple animals, multiple sites in the same animal, multiple sites in multiple animals.

2.4 The Right Tool for the Job

Although Fiber Photometry lacks cellular resolution, this limitation is far from disqualifying for many scientific questions. Neural activity at the spatial scale of neuronal ensembles, for instance, is just as functionally important as single cell activity. After all, it is the coordinated activity of large groups of neurons that produce phenomena such as neuronal oscillations, or in the case of a pathological state, seizure activity. Moreover, neuromodulators such as dopamine can be released from sparse locations within a target brain region and diffuse tens of microns to receptors in a process known as “volume transmission” 11, which entails lower spatial specificity by its very nature. Thus, fiber photometry is suitable for many important questions in neuroscience that are not necessarily about cellular resolution phenomena, but rather pertain to the coordinated activity of ensembles of cells 12.

2.5 When NOT to use Fiber Photometry

Fiber photometry is a powerful and efficient technique for studying neural activity in vivo, but there are many cases in which it would not be suitable even where intuition may make it seem like a tempting option. The first and most obvious limitation is that fiber photometry contains zero spatial resolution at a single recording site reflecting the bulk fluorescence collected by the tip of that fiber. Of course, a major advantage of fiber photometry is its amenability to multi-region recordings which offers spatial resolution of a sort, but even in multi-fiber arrays, a single fiber tip does not spatially resolve individual cells, nor is there any reliable method of inferring single-cell activity from fiber photometry recordings.

ebook-fiber-photometry-part-1-fig8

Figure 8. Effect of signal normalization on fiber photometry traces. Representative photometry traces are shown before and after normalization. Normalization is necessary to remove signal artifacts and control for differences in baseline fluorescence and signal amplitude, enabling comparisons of event-related, relative signal dynamics. However, this procedure is done at the expense of masking differences in absolute signal levels, leading to critical implications for experimental design and data interpretation.

Researchers must also ensure that the target they intend to record is actually detectable via fiber photometry. Consult the literature, the atlases provided by the Allen Institute, or any other relevant resources to determine the density of your targets within the region you intend to record. Sparse objects such as certain types of projections/axon terminals, cells captured via experience-dependent tagging etc. may present considerable difficulty for photometry recording because they may not fall within the light collection field of the fiber tip or they may be small/dim. Even though photometry may be a great tool in principle to address a given scientific question, it may lack the required sensitivity in practice under certain circumstances.

A somewhat more subtle limitation of intensiometric fiber photometry is that measurements of neuronal activity are relative, not absolute. The magnitude of signal dynamics is influenced by many extraneous factors such as happenstance differences in viral expression or the distance of cells from the fiber tip. The very preprocessing steps needed to correct these differences entail normalizing the signal to a baseline, and each animal has its own baseline. As such, between-subjects comparisons of absolute levels of neuronal activity, neurotransmitter release etc. are impossible in principle. Attempting a simple comparison of the magnitude of a GCaMP signal between two groups of mice is often uninformative or worse, highly misleading. Examining between-subjects effects in photometry experiments requires creative workarounds in experimental design/analysis and a careful, subtle understanding of what can actually be inferred from the results. Although a new generation of “Fluorescence Lifetime” sensors and hardware address this issue, the field has not yet seen wide deployment of these methods and they are far more costly to implement. There is much more to say on the topic of fiber photometry experimental design, analysis, and interpretation, and we will explore this in detail in another eBook.

3. Conclusion

Fiber photometry is a powerful and flexible method for studying the ensemble-level neural dynamics underlying behaviour and cognition. It is easy and efficient to implement, high-throughput, and amenable to multi-region, multi-indicator recordings. These attributes make fiber photometry the best choice for many scientific questions, especially those pertaining to multi-region functional connectivity or neuromodulator dynamics. For these reasons, fiber photometry has become a staple workhorse for modern neuroscience research.

If you found this eBook enlightening, we encourage you to have a look at our other eBooks, application notes, and to stay tuned for future releases. The Mightex team is made of experienced researchers from behavioural neuroscience and other biomedical fields. We continually produce new content to bring these fascinating topics to a wider audience and empower our customers with the knowledge to conduct the highest-quality research possible.

References

  1. Adelsberger, H., Garaschuk, O. & Konnerth, A. Cortical calcium waves in resting newborn mice. Nat. Neurosci. 8, 988–990 (2005).
  2. Mochizuki, Y., Joji-Nishino, A., Emoto, K. & Uematsu, A. Distinct neural responses of ventromedial prefrontal cortex-projecting nucleus reuniens neurons during aversive memory extinction. Mol. Brain 18, 18 (2025).
  3. Aklan, I. et al. Dorsal raphe serotonergic neurons suppress feeding through redundant forebrain circuits. Mol. Metab. 69, 101676 (2023).
  4. Kaur, J. & Berg, R. W. Viral strategies for targeting spinal neuronal subtypes in adult wild-type rodents. Sci. Rep. 12, 8627 (2022).
  5. Li, H., Sung, H. H. & Lau, C. G. Activation of somatostatin-expressing neurons in the lateral septum improves stress-induced depressive-like behaviors in mice. Pharmaceutics 14, 2253 (2022).
  6. Navabpour, S., Kwapis, J. L. & Jarome, T. J. A neuroscientist’s guide to transgenic mice and other genetic tools. Neurosci. Biobehav. Rev. 108, 732–748 (2020).
  7. Warlow, S. M. et al. Mesoaccumbal glutamate neurons drive reward via glutamate release but aversion via dopamine co-release. Neuron 112, 488–499.e5 (2024).
  8. Deng, F. et al. Improved green and red GRAB sensors for monitoring spatiotemporal serotonin release in vivo. Nat. Methods 21, 692–702 (2024).
  9. Feng, J. et al. Monitoring norepinephrine release in vivo using next-generation GRABNE sensors. Neuron 112, 1930–1942.e6 (2024).
  10. Labouesse, M. A., Cola, R. B. & Patriarchi, T. GPCR-based dopamine sensors-A detailed guide to inform sensor choice for in vivo imaging. Int. J. Mol. Sci. 21, 8048 (2020).
  11. Özçete, Ö. D., Banerjee, A. & Kaeser, P. S. Mechanisms of neuromodulatory volume transmission. Mol. Psychiatry 29, 3680–3693 (2024).
  12. Kielbinski, M. & Bernacka, J. Fiber photometry in neuroscience research: principles, applications, and future directions. Pharmacol. Rep. 76, 1242–1255 (2024).